Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Lancet Reg Health West Pac ; 13: 100202, 2021 Aug.
Article in English | MEDLINE | ID: covidwho-2259348
2.
Nat Commun ; 13(1): 907, 2022 02 16.
Article in English | MEDLINE | ID: covidwho-1692613

ABSTRACT

Population antibody surveillance helps track immune responses to COVID-19 vaccinations at scale, and identify host factors that may affect antibody production. We analyse data from 212,102 vaccinated individuals within the REACT-2 programme in England, which uses self-administered lateral flow antibody tests in sequential cross-sectional community samples; 71,923 (33.9%) received at least one dose of BNT162b2 vaccine and 139,067 (65.6%) received ChAdOx1. For both vaccines, antibody positivity peaks 4-5 weeks after first dose and then declines. At least 21 days after second dose of BNT162b2, close to 100% of respondents test positive, while for ChAdOx1, this is significantly reduced, particularly in the oldest age groups (72.7% [70.9-74.4] at ages 75 years and above). For both vaccines, antibody positivity decreases with age, and is higher in females and those with previous infection. Antibody positivity is lower in transplant recipients, obese individuals, smokers and those with specific comorbidities. These groups will benefit from additional vaccine doses.


Subject(s)
Aging/immunology , Antibodies, Viral/blood , BNT162 Vaccine/immunology , ChAdOx1 nCoV-19/immunology , SARS-CoV-2/immunology , Age Factors , Aged , Antibody Formation/immunology , COVID-19/epidemiology , COVID-19/prevention & control , Cross-Sectional Studies , England/epidemiology , Female , Humans , Immunization Programs , Immunoglobulin G/blood , Male , Middle Aged , Prospective Studies , Sex Factors , Vaccination
3.
Sci Rep ; 12(1): 1885, 2022 02 03.
Article in English | MEDLINE | ID: covidwho-1671623

ABSTRACT

At-home sampling is key to large scale seroprevalence studies. Dried blood spot (DBS) self-sampling removes the need for medical personnel for specimen collection but facilitates specimen referral to an appropriately accredited laboratory for accurate sample analysis. To establish a highly sensitive and specific antibody assay that would facilitate self-sampling for prevalence and vaccine-response studies. Paired sera and DBS eluates collected from 439 sero-positive, 382 sero-negative individuals and DBS from 34 vaccine recipients were assayed by capture ELISAs for IgG and IgM antibody to SARS-CoV-2. IgG and IgM combined on DBS eluates achieved a diagnostic sensitivity of 97.9% (95%CI 96.6 to 99.3) and a specificity of 99.2% (95% CI 98.4 to 100) compared to serum, displaying limits of detection equivalent to 23 and 10 WHO IU/ml, respectively. A strong correlation (r = 0.81) was observed between serum and DBS reactivities. Reactivity remained stable with samples deliberately rendered inadequate, (p = 0.234) and when samples were accidentally damaged or 'invalid'. All vaccine recipients were sero-positive. This assay provides a secure method for self-sampling by DBS with a sensitivity comparable to serum. The feasibility of DBS testing in sero-prevalence studies and in monitoring post-vaccine responses was confirmed, offering a robust and reliable tool for serological monitoring at a population level.


Subject(s)
Antibodies, Viral/blood , COVID-19 Testing/methods , COVID-19/diagnosis , COVID-19/epidemiology , Dried Blood Spot Testing/methods , Immunoglobulin G/blood , Immunoglobulin M/blood , SARS-CoV-2/immunology , Specimen Handling/methods , Biomarkers/blood , COVID-19/immunology , COVID-19/virology , COVID-19 Vaccines/immunology , Feasibility Studies , Female , Humans , Male , Sensitivity and Specificity , Seroepidemiologic Studies
5.
Open Forum Infect Dis ; 8(7): ofab267, 2021 Jul.
Article in English | MEDLINE | ID: covidwho-1376326

ABSTRACT

BACKGROUND: Genotype 6 is the most genetically diverse lineage of hepatitis C virus, and it predominates in Vietnam. It can be treated with sofosbuvir with daclatasvir (SOF/DCV), the least expensive treatment combination globally. In regional guidelines, longer treatment durations of SOF/DCV (24 weeks) are recommended for cirrhotic individuals, compared with other pangenotypic regimens (12 weeks), based on sparse data. Early on-treatment virological response may offer means of reducing length and cost of therapy in patients with liver fibrosis. METHODS: In this prospective trial in Vietnam, genotype 6-infected adults with advanced liver fibrosis or compensated cirrhosis were treated with SOF/DCV. Day 14 viral load was used to guide duration of therapy: participants with viral load <500 IU/mL at day 14 were treated with 12 weeks of SOF/DCV and those ≥500 IU/mL received 24 weeks. Primary endpoint was sustained virological response (SVR). RESULTS: Of 41 individuals with advanced fibrosis or compensated cirrhosis who commenced treatment, 51% had genotype 6a and 34% had 6e. The remainder had 6h, 6k, 6l, or 6o. One hundred percent had viral load <500 IU/mL by day 14, meaning that all received 12 weeks of SOF/DCV. One hundred percent achieved SVR12 despite a high frequency of putative NS5A inhibitor resistance-associated substitutions at baseline. CONCLUSIONS: Prescribing 12 weeks of SOF/DCV results in excellent cure rates in this population. These data support the removal of costly genotyping in countries where genotype 3 prevalence is <5%, in keeping with World Health Organization guidelines. NS5A resistance-associated mutations in isolation do not affect efficacy of SOF/DCV therapy. Wider evaluation of response-guided therapy is warranted.

7.
Clin Infect Dis ; 72(9): e384-e393, 2021 05 04.
Article in English | MEDLINE | ID: covidwho-1216633

ABSTRACT

BACKGROUND: This study assesses acceptability and usability of home-based self-testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies using lateral flow immunoassays (LFIA). METHODS: We carried out public involvement and pilot testing in 315 volunteers to improve usability. Feedback was obtained through online discussions, questionnaires, observations, and interviews of people who tried the test at home. This informed the design of a nationally representative survey of adults in England using two LFIAs (LFIA1 and LFIA2) which were sent to 10 600 and 3800 participants, respectively, who provided further feedback. RESULTS: Public involvement and pilot testing showed high levels of acceptability, but limitations with the usability of kits. Most people reported completing the test; however, they identified difficulties with practical aspects of the kit, particularly the lancet and pipette, a need for clearer instructions and more guidance on interpretation of results. In the national study, 99.3% (8693/8754) of LFIA1 and 98.4% (2911/2957) of LFIA2 respondents attempted the test and 97.5% and 97.8% of respondents completed it, respectively. Most found the instructions easy to understand, but some reported difficulties using the pipette (LFIA1: 17.7%) and applying the blood drop to the cassette (LFIA2: 31.3%). Most respondents obtained a valid result (LFIA1: 91.5%; LFIA2: 94.4%). Overall there was substantial concordance between participant and clinician interpreted results (kappa: LFIA1 0.72; LFIA2 0.89). CONCLUSIONS: Impactful public involvement is feasible in a rapid response setting. Home self-testing with LFIAs can be used with a high degree of acceptability and usability by adults, making them a good option for use in seroprevalence surveys.


Subject(s)
COVID-19 , SARS-CoV-2 , Adult , Antibodies, Viral , England , Humans , Population Surveillance , Self-Testing , Seroepidemiologic Studies
8.
Lancet Reg Health Eur ; 4: 100098, 2021 May.
Article in English | MEDLINE | ID: covidwho-1213413

ABSTRACT

BACKGROUND: The time-concentrated nature of the first wave of the COVID-19 epidemic in England in March and April 2020 provides a natural experiment to measure changes in antibody positivity at the population level before onset of the second wave and initiation of the vaccination programme. METHODS: Three cross-sectional national surveys with non-overlapping random samples of the population in England undertaken between late June and September 2020 (REACT-2 study). 365,104 adults completed questionnaires and self-administered lateral flow immunoassay (LFIA) tests for IgG against SARS-CoV-2. FINDINGS: Overall, 17,576 people had detectable antibodies, a prevalence of 4.9% (95% confidence intervals 4.9, 5.0) when adjusted for test characteristics and weighted to the adult population of England. The prevalence declined from 6.0% (5.8, 6.1), to 4.8% (4.7, 5.0) and 4.4% (4.3, 4.5), over the three rounds of the study a difference of -26.5% (-29.0, -23.8). The highest prevalence and smallest overall decline in positivity was in the youngest age group (18-24 years) at -14.9% (-21.6, -8.1), and lowest prevalence and largest decline in the oldest group (>74 years) at -39.0% (-50.8, -27.2). The decline from June to September 2020 was largest in those who did not report a history of COVID-19 at -64.0% (-75.6, -52.3), compared to -22.3% (-27.0, -17.7) in those with SARS-CoV-2 infection confirmed on PCR. INTERPRETATION: A large proportion of the population remained susceptible to SARS-CoV-2 infection in England based on naturally acquired immunity from the first wave. Widespread vaccination is needed to confer immunity and control the epidemic at population level. FUNDING: This work was funded by the Department of Health and Social Care in England.

9.
BMJ ; 372: n423, 2021 03 02.
Article in English | MEDLINE | ID: covidwho-1115122

ABSTRACT

OBJECTIVE: To evaluate the performance of new lateral flow immunoassays (LFIAs) suitable for use in a national coronavirus disease 2019 (covid-19) seroprevalence programme (real time assessment of community transmission 2-React 2). DESIGN: Diagnostic accuracy study. SETTING: Laboratory analyses were performed in the United Kingdom at Imperial College, London and university facilities in London. Research clinics for finger prick sampling were run in two affiliated NHS trusts. PARTICIPANTS: Sensitivity analyses were performed on sera stored from 320 previous participants in the React 2 programme with confirmed previous severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. Specificity analyses were performed on 1000 prepandemic serum samples. 100 new participants with confirmed previous SARS-CoV-2 infection attended study clinics for finger prick testing. INTERVENTIONS: Laboratory sensitivity and specificity analyses were performed for seven LFIAs on a minimum of 200 serum samples from participants with confirmed SARS-CoV-2 infection and 500 prepandemic serum samples, respectively. Three LFIAs were found to have a laboratory sensitivity superior to the finger prick sensitivity of the LFIA currently used in React 2 seroprevalence studies (84%). These LFIAs were then further evaluated through finger prick testing on participants with confirmed previous SARS-CoV-2 infection: two LFIAs (Surescreen, Panbio) were evaluated in clinics in June-July 2020 and the third LFIA (AbC-19) in September 2020. A spike protein enzyme linked immunoassay and hybrid double antigen binding assay were used as laboratory reference standards. MAIN OUTCOME MEASURES: The accuracy of LFIAs in detecting immunoglobulin G (IgG) antibodies to SARS-CoV-2 compared with two reference standards. RESULTS: The sensitivity and specificity of seven new LFIAs that were analysed using sera varied from 69% to 100%, and from 98.6% to 100%, respectively (compared with the two reference standards). Sensitivity on finger prick testing was 77% (95% confidence interval 61.4% to 88.2%) for Panbio, 86% (72.7% to 94.8%) for Surescreen, and 69% (53.8% to 81.3%) for AbC-19 compared with the reference standards. Sensitivity for sera from matched clinical samples performed on AbC-19 was significantly higher with serum than finger prick at 92% (80.0% to 97.7%, P=0.01). Antibody titres varied considerably among cohorts. The numbers of positive samples identified by finger prick in the lowest antibody titre quarter varied among LFIAs. CONCLUSIONS: One new LFIA was identified with clinical performance suitable for potential inclusion in seroprevalence studies. However, none of the LFIAs tested had clearly superior performance to the LFIA currently used in React 2 seroprevalence surveys, and none showed sufficient sensitivity and specificity to be considered for routine clinical use.


Subject(s)
COVID-19 Serological Testing , COVID-19/diagnosis , Immunoassay , SARS-CoV-2/isolation & purification , Adult , Antibodies, Viral/blood , COVID-19/blood , COVID-19/epidemiology , Female , Humans , Male , Middle Aged , SARS-CoV-2/immunology , Sensitivity and Specificity , Seroepidemiologic Studies , United Kingdom
10.
Thorax ; 75(12): 1082-1088, 2020 12.
Article in English | MEDLINE | ID: covidwho-717419

ABSTRACT

BACKGROUND: Accurate antibody tests are essential to monitor the SARS-CoV-2 pandemic. Lateral flow immunoassays (LFIAs) can deliver testing at scale. However, reported performance varies, and sensitivity analyses have generally been conducted on serum from hospitalised patients. For use in community testing, evaluation of finger-prick self-tests, in non-hospitalised individuals, is required. METHODS: Sensitivity analysis was conducted on 276 non-hospitalised participants. All had tested positive for SARS-CoV-2 by reverse transcription PCR and were ≥21 days from symptom onset. In phase I, we evaluated five LFIAs in clinic (with finger prick) and laboratory (with blood and sera) in comparison to (1) PCR-confirmed infection and (2) presence of SARS-CoV-2 antibodies on two 'in-house' ELISAs. Specificity analysis was performed on 500 prepandemic sera. In phase II, six additional LFIAs were assessed with serum. FINDINGS: 95% (95% CI 92.2% to 97.3%) of the infected cohort had detectable antibodies on at least one ELISA. LFIA sensitivity was variable, but significantly inferior to ELISA in 8 out of 11 assessed. Of LFIAs assessed in both clinic and laboratory, finger-prick self-test sensitivity varied from 21% to 92% versus PCR-confirmed cases and from 22% to 96% versus composite ELISA positives. Concordance between finger-prick and serum testing was at best moderate (kappa 0.56) and, at worst, slight (kappa 0.13). All LFIAs had high specificity (97.2%-99.8%). INTERPRETATION: LFIA sensitivity and sample concordance is variable, highlighting the importance of evaluations in setting of intended use. This rigorous approach to LFIA evaluation identified a test with high specificity (98.6% (95%CI 97.1% to 99.4%)), moderate sensitivity (84.4% with finger prick (95% CI 70.5% to 93.5%)) and moderate concordance, suitable for seroprevalence surveys.


Subject(s)
Antibodies, Viral/analysis , COVID-19/diagnosis , Immunoassay/methods , Pandemics , SARS-CoV-2/immunology , Adult , COVID-19/epidemiology , COVID-19/virology , DNA, Viral/analysis , Female , Follow-Up Studies , Humans , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , SARS-CoV-2/genetics , Seroepidemiologic Studies
SELECTION OF CITATIONS
SEARCH DETAIL